Products
Electricity
SPM20
- Compact Multi-Circuit Metering
- The SPM20 comprises the main metering unit combined with bus connected CT's, solid-core or split-core, up to 63A per circuit
- 30 single phase, 2-wire / 10 x 3 phase, 4-wire
- kWh, kVArh
- V, I, kW, kVAr, kVA, P.F., Hz
- 50A split core CT, bus connected
- 63A solid core CT, bus connected
- Modbus RTU RS485
SPM91
- Compact Single-phase c/w Modbus 485
- Compact kWh meter, ideal for building management systems.
- Single phase 220...240Vac
- 63Amp direct connected
- Modbus RTU 485 communications
- Pulse output
- IEC 62053-21 (Class 1.0)
- DIN rail mounting
- 100mm x 36mm x 65mm
SPM93
- Compact three-phase c/w Modbus 485
- Compact kWh/kVArh meter, ideal for building management systems.
- Three phase 220/380...240/415Vac
- 63Amp direct connected or 5Amp CT connected options
- Modbus RTU 485 communications
- Pulse output x 2
- IEC 62053-21/23 (Class 1.0)
- DIN rail mounting
- 100mm x 72mm x 65mm
PMAC201-HW
- 12 Modular-Channel c/w Modbus
- 4 x 3-phase or 12 x single-phase, kWh & kVArh meter, with Modbus 485 communication.
Supplied c/w with power supply and 12 x clip on CT's.
- 3 x 230/400Vac
- 12 x 100 amp (max. primary current)
- Data log memory
- Modbus RTU RS485 communication
- DIN Rail mounting
- 100mm x 75mm x 80.1mm
SPM33
- Panel mount Multi-function meter c/w Modbus 485
- The SPM33 is the perfect solution for networked three-phase flush panel metering at a great price-point.
- 3 x 220/380...240/415Vac
- 3 x 5 Amp, CT connected
- Active & reactive energy
- Modbus RTU 485 communications
- Digital input x 2
- IEC 62053-21/23 (Class 1.0)
- Flush panel mounting
PMAC770 c/w Modbus 485 & optional Modbus TCP/IP
- PMAC770-V6-F1-P1
- Panel mount 3-phase, CT connected meter with Modbus RS485 as standard and TCP/IP module option
The V6 version is 240/415Vac, 5A CT connected. Other nominal voltage ratings available as outlined in the data sheet
PMAC770 c/w BACnet MS/TP or P1 FLN, and Modbus
- PMAC770-BA-V6-F1-P1
- PMAC770 meter as above, delivered complete with BACnet MS/TP / P1 FLN comms module
All settings of the comms module are made via the meter display / keypad:
- Protocol (default BACnet MS/TP, user switchable to P1 FLN)
- Baud rate
- Address
- BACnet Device Instance (DI)
- BACnet Maximum Master (MM)
Module manual updated 10/08/2013
SCT-T24 / SCT-T36
- Split Current Transformers
- Compact split CT's up to 400A primary, with 5A secondary
- Class 1.0
- SCT-T24: 100A
- SCT-T36: 200A, 300A, 400A
D363
- Current Transformers
- 5 Amp CT, 3 in 1
- 3 phases in one compact unit
- 50A….500A
- 600Vac rated
- Class 0.5
- DIN rail or gear-plate mounting
MES60
- Current Transformers
- 5 Amp CT
- 1 required per phase
- 600A….1200A
- 600Vac rated
- Class 0.5
- DIN rail or gear-plate mounting
PMAC901-C-1-100
- Single Phase
- kWh Meter
- Direct Connected 100 Amp
- 2-wire, 230Vac 50 Hz
- Class 1.0
- Modbus RTU
- Impulse Output, open collector
- DIN rail mounting
DEM011-20(80)
- Single Phase
- kWh Meter
- Direct Connected 80 Amp
- 2-wire, 230Vac 50 Hz
- Class 1.0
- Impulse Output, open collector
- DIN rail mounting
DEM021-15(90)
- Three Phase
- kWh Meter
- Direct Connected 90 Amp
- 4-wire, 230/400Vac 50 Hz
- Class 1.0
- Impulse Output, open collector
- DIN rail mounting
KR3032 (Rail 303)
- Three Phase
- kWh Meter, Modbus
- CT Connected 5(6) Amp
- 4-wire, 230/400Vac 50 Hz
- Class 1.0
- Modbus RTU
- Impulse Output, open collector
- DIN rail mounting
KC4002 (Cube 400)
- Three Phase
- Combi Meter, Modbus
- CT Connected 5(6) Amp
- 4-wire, 230/400Vac 50 Hz
- Class 1.0
- Modbus RTU
- Impulse Output, open collector
- Flush panel mounting